ECOTOXICOLOGY ASSESSMENT AND CHEMICAL CHARACTERISTICS OF WATER SAMPLES AFTER MINING AND PROCESSING OF URANIUM.

MOOS, M.; HOLUBOVÁ, Z.; SOMMER, L.

Original Title

ECOTOXICOLOGY ASSESSMENT AND CHEMICAL CHARACTERISTICS OF WATER SAMPLES AFTER MINING AND PROCESSING OF URANIUM.

English Title

ECOTOXICOLOGY ASSESSMENT AND CHEMICAL CHARACTERISTICS OF WATER SAMPLES AFTER MINING AND PROCESSING OF URANIUM.

Type

Conference proceedings

Original Abstract

A study has been conducted for the determination of eight elements (Be, V, Co, Ni, Y, Cd, Pb and Th) by inductively coupled plasma mass spectromentry (ICP-MS) in naturals waters and waters after mining and processing of uranium. An ICP-MS spectrometer Agilent 7500ce, with a plasma generator of 27.12 MHz, power output 1500 W and concentric nebulizer MicroMist with a cooled Scott chamber was used. The matrix effects was eliminated by using a solution of internal standards 6Li was used for 9Be, 45Sc (51V), 72Ge (59Co, 60Ni, 89Y), 103Rh (111Cd), 209Bi (206Pb, 207Pb, 208Pb, 232Th). Monitored interfering elements were K+, Na+, NH4+, Fe2+, Ca2+, Mg2+, Al3+, NO3-, NO2-, SO42-, Cl-, HCO3-. The non-polar sorbents based on Silica (C18, C8 and Phenyl) were conditioned with the Benzyldimethyltetradecylammonium chloride (Zephyramine) or 1-etoxycarbonyl-pentadecyltrimethylammonium bromide (Septonex). The sorption process for the preconcentration of target elements was realized in the presence of 4-(2-pyridylazo) resorcinol, Ammonium pyrrolidinedithiocarbamate, 8-Hydroxyquinoline-5-sulphonic acid and Alizarine S at pH 5-9. The elution mixture was acetone and ethanol (1:1) in presence of 1 mol?l-1 HCl. The excess of acid and organic solvents were evaporated in Teflon dish prior to the determination by ICP-MS.

English abstract

A study has been conducted for the determination of eight elements (Be, V, Co, Ni, Y, Cd, Pb and Th) by inductively coupled plasma mass spectromentry (ICP-MS) in naturals waters and waters after mining and processing of uranium. An ICP-MS spectrometer Agilent 7500ce, with a plasma generator of 27.12 MHz, power output 1500 W and concentric nebulizer MicroMist with a cooled Scott chamber was used. The matrix effects was eliminated by using a solution of internal standards 6Li was used for 9Be, 45Sc (51V), 72Ge (59Co, 60Ni, 89Y), 103Rh (111Cd), 209Bi (206Pb, 207Pb, 208Pb, 232Th). Monitored interfering elements were K+, Na+, NH4+, Fe2+, Ca2+, Mg2+, Al3+, NO3-, NO2-, SO42-, Cl-, HCO3-. The non-polar sorbents based on Silica (C18, C8 and Phenyl) were conditioned with the Benzyldimethyltetradecylammonium chloride (Zephyramine) or 1-etoxycarbonyl-pentadecyltrimethylammonium bromide (Septonex). The sorption process for the preconcentration of target elements was realized in the presence of 4-(2-pyridylazo) resorcinol, Ammonium pyrrolidinedithiocarbamate, 8-Hydroxyquinoline-5-sulphonic acid and Alizarine S at pH 5-9. The elution mixture was acetone and ethanol (1:1) in presence of 1 mol?l-1 HCl. The excess of acid and organic solvents were evaporated in Teflon dish prior to the determination by ICP-MS.

Keywords

Ekotoxicology, ICP-MS, uranium

Key words in English

Ekotoxicology, ICP-MS, uranium

Authors

MOOS, M.; HOLUBOVÁ, Z.; SOMMER, L.

RIV year

2011

Released

04.10.2010

Location

Rome

ISBN

978-88-8286-228-2

Pages from

77

Pages to

77

Pages count

1

Full text in the Digital Library

BibTex

@proceedings{BUT66134,
  editor="Martin {Moos} and Zuzana {Holubová} and Lumír {Sommer}",
  title="ECOTOXICOLOGY ASSESSMENT AND CHEMICAL CHARACTERISTICS OF WATER SAMPLES AFTER MINING AND PROCESSING OF URANIUM.",
  year="2010",
  pages="77--77",
  address="Rome",
  isbn="978-88-8286-228-2"
}