Comparative Evaluation of Membrane Contactor and Stripping Device for Ammonia Separation
LINDOVSKÝ, J. MAYEROVÁ, K. KALIVODA, J. KRIŠTOF, O.
Originální název
Comparative Evaluation of Membrane Contactor and Stripping Device for Ammonia Separation
Typ
článek v časopise ve Scopus, Jsc
Jazyk
angličtina
Originální abstrakt
This study compares two semi-operational devices for ammonia separation from high-ammonia wastewater: a membrane contactor and a stripping device. The membrane contactor utilizes a bundle of hollow-fibre membranes, facilitating the transfer of ammonia nitrogen from the outer shell into an acidic solution inside the fibres. In contrast, the stripping device operates across various temperatures, with ammonia removal assessed by absorption into an acidic solution. Both devices were tested using a model solution simulating high-ammonia liquid digestate from a biogas plant to determine their optimal operating conditions. The pilot experiments evaluated separation efficiency and highlighted each technology's unique advantages and limitations. Our results demonstrate that the membrane contactor achieved the highest efficiency using a KH₂PO₄ solution, long fibres, and elevated temperature, resulting in complete ammonia removal within 240 minutes without pH adjustment, with 50% efficiency at 60 minutes. Further measurements without any condition adjustments resulted in a final separation efficiency of 69 ± 6% after 300 minutes, with 50% efficiency achieved at 181 minutes. Subsequent experiments using a KHSO₄ absorption solution helped to investigate optimal conditions and process kinetics, but the separation efficiency was lower compared to using KH₂PO₄.When using KHSO₄, a maximum efficiency of 93 ± 3% was obtained in 90 minutes after adjusting the pH to around 12. However, while this pH increase enhanced ammonia desorption, the high base consumption makes it economically unfavourable. In comparison, the stripping device achieved its best results at a pH of 10.5, a temperature of 60°C, and an airflow rate of 120 l/min, reaching 85% efficiency within 50 minutes. At a lower pH of 9, the efficiency dropped to 64% over the same time period. These results highlight the stripping device's potential for faster ammonia removal, though efficiency is heavily dependent on pH and airflow conditions.
Klíčová slova
Ammonia separation; Hollow-fiber membranes; Liquid digestate; Stripping device; Wastewater treatment
Autoři
LINDOVSKÝ, J.; MAYEROVÁ, K.; KALIVODA, J.; KRIŠTOF, O.
Vydáno
1. 3. 2025
Nakladatel
Avestia Publishing
ISSN
2368-6111
Periodikum
Journal of Fluid Flow, Heat and Mass Transfer
Ročník
12
Číslo
1
Stát
Kanada
Strany od
88
Strany do
94
Strany počet
7
URL
BibTex
@article{BUT197852,
author="Jiří {Lindovský} and Kateřina {Mayerová} and Josef {Kalivoda} and Ondřej {Krištof}",
title="Comparative Evaluation of Membrane Contactor and Stripping Device for Ammonia Separation",
journal="Journal of Fluid Flow, Heat and Mass Transfer",
year="2025",
volume="12",
number="1",
pages="88--94",
doi="10.11159/jffhmt.2025.009",
issn="2368-6111",
url="https://jffhmt.avestia.com/2025/009.html"
}